 www.murata-ps.com
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
Typical unit
FEATURES
3.3 Volts DC fixed output up to 50 Amps Industry standard quarter brick 2.3" x 1.45" x 0.39" open frame package Wide range 36 to 75 Vdc input voltages with 2250 Volt Basic isolation Double lead-free assembly and attachment for RoHS standards Up to 165 Watts total output power High efficiency synchronous rectifier topology Stable no-load operation with no required external components Operating temperature range -40 to +85 C. with no heat sink required Designed to meet UL/EN 60950-1, CSA-C22.2 No. 60950-1, safety approvals Extensive self-protection, current limiting and shut down features
PRODUCT OVERVIEW
nverters, Unique among quarter-brick DC/DC converters, the rent HPQ series offers very high output current (up to 50 Amps) in an industry standard "quarter brick" package requiring no heat sink. The HPQ series delivers up to 165 Watts fixed voltage output for printed circuit board mounting. Wide range inputs on the 2.3" x 1.45" x 0.39" converter are 36 to 75 Volts DC (48 Volts nominal), ideal for datacom and telecom systems. The fixed output voltage is regulated to within 1% and may be trimmed within 10% of nominal output. Advanced automated surface mount assembly and planar magnetics deliver full magnetic and optical isolation with Basic protection up to 2250 Volts. To power digital systems, the outputs offer fast settling to current steps and tolerance of higher capacitive loads. Excellent ripple and noise specifications assure compatibility to CPU's, ASIC's, programmable logic and FPGA's. No minimum load is required. For systems needing controlled startup/ shutdown, an external remote On/Off c control may use either positive or negative polarity. Remote Sense inputs compensate for resistive line drops at high currents. A wealth of self-protection features avoid problems with both the converter and external circuits. These include input undervoltage lockout and overtemperature shutdown using an on-board temperature sensor. Excessive overcurrents limit their power using the "hiccup" autorestart technique and the outputs may be short-circuited indefinitely. Additional safety features include output overvoltage protection and reverse conduction elimination. The synchronous rectifier topology offers high efficiency for minimal heat buildup and "no heat sink" operation. The HPQ series is designed to meet full safety certifications to UL/EN/IEC/CSA 60950-1 and RFI/EMI conducted/radiated emission compliance to FCC part 15 class B.
APPLICATIONS
Embedded systems, datacom and telecom installations Disk farms, data centers and cellular repeater sites Remote sensor systems, dedicated controllers
+VIN (3)
Instrumentation systems, R&D platforms, automated test fixtures Data concentrators, voice forwarding and speech processing systems
+SENSE (7) +VOUT (8)
SWITCH CONTROL -VOUT (4)
-VIN (1) PULSE TRANSFORMER PWM CONTROLLER OPTO ISOLATION
INPUT UNDERVOLTAGE, INPUT OVERVOLTAGE, AND OUTPUT OVERVOLTAGE COMPARATORS REFERENCE & ERROR AMP
-SENSE (5)
VOUT TRIM (6)
REMOTE ON/OFF CONTROL (2)
Figure 1. Simplified Schematic Typical topology is shown
For full details go to www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 1 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
ORDERING GUIDE Output R/N (mV pk-pk) IOUT VOUT (Amps, Power (Volts) max.) (Watts) Typ. Max. Regulation (Max.) Line Input Efficiency Min. Typ. Dimensions (inches) Package Dimensions (mm) Pinout
Root Model HPQ-3.3/50-D48N-C
IIN full VIN Nom. Range IIN no load Load (Volts) (Volts) load (mA) (Amps)
3.3
50
165
50
100 0.2% 0.2%
48
36-75
80
3.82
88%
90%
1.45x2.3x0.39
36.8x58.4x9.9
P32
Please refer to the part number structure for additional ordering information and options. All specifications are at nominal line voltage and full load, +25 deg.C. unless otherwise noted. See detailed specifications. Output capacitors are 1 F ceramic || 10 F electrolytic with no input caps.These caps are necessary for our test equipment and may not be needed for your application.
MECHANICAL SPECIFICATIONS
B
1.860 (47.2)
A
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
1.00 (25.4)
Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 Components are shown for reference only.
1.45 (36.8)
Screw length must not go through baseplate.
#M3-THREAD X 0.15 DEEP TYPICAL (4) PLACES
BASEPLATE Optional baseplate
0.015 (0.4) min. clearance between highest component and pin shoulders PINS 1-3, 5-7: 0.040 0.001 (1.016 0.025) PINS 4 & 8: 0.060 0.001 (1.52 0.025)
0.50 (12.7) With Baseplate 0.40 (10.2) Without Baseplate
I/O Connections (pin side view) Pin 1 2 3 4 Function P32 Neg. Input Remote On/Off Control Pos. Input Neg. Output Pin 5 6 7 8 Function P32 Neg. Sense Output Trim Pos. Sense Pos. Output
1
1.30 (33.0)
0.18 (4.6)
B
Component locations are typical and may vary between models.
2.30 (58.4) 2.00 (50.8)
A A
Important! Always connect the sense pins. If they are not connected to a remote load, wire each sense pin to its respective voltage output at the converter pins.
2 3
4 5 6 7 8
B
0.600 (15.2) 4 EQ. SP. @ 0.150 (3.8)
Optional mounting holes, 4 places
2.15 (54.6)
BOTTOM VIEW
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 2 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
PART NUMBER STRUCTURE
HPQ - 3.3 / 50 - D48 N B
Family Series: High Power Quarter Brick Nominal Output Voltage
H LX - C
RoHS Hazardous Materials compliance C = RoHS-6 (no lead), standard Y = RoHS-5 (with lead), optional, special quantity order Pin length option Blank = standard pin length 0.180 in. (4.6 mm) L1 = 0.110 in. (2.79 mm)* L2 = 0.145 in. (3.68 mm)* *Special quantity order required Conformal coating (optional) Blank = no coating, standard H = Coating added, optional, special quantity order
Maximum Rated Output : Current in Amps Input Voltage Range: D48 = 36-75 Volts (48V nominal)
Baseplate (optional) Blank = No baseplate, standard B = Baseplate installed, optional quantity order
On/Off Control Polarity N = Negative polarity, standard P = Positive polarity, optional
Note: Some model combinations may not be available. Contact Murata Power Solutions for availability.
Performance and Functional Specifications All specifications are typical unless noted. See Note 1.
Input Input Voltage Range Recommended External Fuse Start-Up Voltage Undervoltage Shutdown Overvoltage Shutdown Reflected (Back) Ripple Current (Note 2) Internal Input Filter Type Reverse Polarity Protection (Note 15) Input Current: Full Load Conditions Inrush Transient Shutdown Mode (Off, UV, OT) Output Short Circuit No Load, 3.3Vout Low Line (Vin=Vmin, 3.3Vout) Remote On/Off Control (Note 5) Positive Logic ("P" suffix) Negative Logic ("N" suffix) Current ON = +2.5 V. to +15 V. max. or open pin OFF = 0 to +1 V. max. or ground pin ON = -0.1 V. to +0.8 V. max. or ground pin OFF = +2.5 V. to +15 V. max. or open pin 1 mA See Ordering Guide. 0.05 A2Sec. 10 mA 50 mA 80 mA 5.21 Amps See Ordering Guide. 10 Amps 33.0 Volts 32.0 Volts None, see application notes. 20 mA pk-pk Pi-type See fuse information
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 3 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
Output Minimum Loading Maximum Output Power Accuracy (50% load) Overvoltage Protection (Note 7) Temperature Coefficient Ripple/Noise (20 MHz bandwidth) Line/Load Regulation (See Tech. Notes) Efficiency Remote Sense Compensation Maximum Capacitive Loading, low ESR Current Limit Inception (98% of Vout setting) Short Circuit Mode (Notes 6, 12) Short Circuit Current Output Protection Method Short Circuit Duration Isolation Isolation Voltage Input to Output Input to Baseplate Baseplate to Output Isolation Resistance Isolation Capacitance Isolation Safety Rating Dynamic Characteristics Dynamic Load Response Turn-On Time Remote On/Off Time Switching Frequency Environmental Calculated MTBF (Note 4) Operating Temperature Range (no baseplate) Maximum Baseplate Operating Temperature Storage Temperature Range Thermal Protection/Shutdown (Case temp. is measured in the center) Relative Humidity Physical Outline Dimensions Weight Electromagnetic Interference (may require external filter) Safety (designed to meet) See Mechanical Specifications 1.06 ounces (30 grams) FCC Part 15, EN55022, Class B, conducted and radiated UL/cUL 60950-1 CSA-C22.2 No. 60950-1 IEC/EN 60950-1 TBC -40 to +85 C (with derating) +100 C -55 to +125 C +115 C 85%/+85 C 200 Sec to within 1% of final value. (50-75-50% load step) 10 mSec for Vout regulated 10 mSec for Vout regulated 400 40 KHz 2250 Vdc min. 1500 Vdc min. 1500 Vdc min. 10 Megohms 1000 pF Basic insulation 5 Amps Hiccup autorecovery upon overload removal. (See note 12) Continuous, no damage (output shorted to ground) No minimum load 166.6 Watts 1 % of Vsetting. See note 16. 4 Volts 0.02% per C. of Vout range See Ordering Guide and note 8. See Ordering Guide and note 10. See Ordering Guide +10% max. deviation from output 10,000 F max. See note 11. 59 Amps (after warm up) See note 12.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 4 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
Absolute Maximum Ratings Input Voltage Continuous or transient Output Power On/Off Control Input Reverse Polarity Protection Output Current Storage Temperature Lead Temperature 75 Volts max. 166.6 Watts max. 0V. min. to +15 V. max. See Fuse section Current-limited. Devices can withstand sustained short circuit without damage. -55 to +125 C See soldering guidelines.
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied nor recommended. CAUTION: This product is not internally fused. To comply with safety agency certifications and to avoid injury to personnel or equipment, the user must supply an external slow-blow fuse to the input terminals. See fuse information.
Specification Notes
(1) All models are tested and specified with external 1||10 F output capacitors and no external input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. All specifications are typical unless noted. General conditions for Specifications are +25 C, Vin=nominal, Vout=nominal, full load. Adequate airflow must be supplied for extended testing under power. (2) Reflected Input Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin=33 F, 100V, Cbus=220 F, 100V electrolytic, Lbus=12 H. (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the Derating curve. All Derating curves are presented at sea level altitude. Be aware of reduced power dissipation with increasing density altitude. (4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, Tpcboard=+25 C, full output load, natural air convection. (5) The On/Off Control is normally controlled by a switch, relay or open collector or open drain transistor. But it may also be driven with external logic or by applying appropriate external voltages which are referenced to Input Common. (6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. (7) The outputs are not intended to sink appreciable reverse current. This may damage the outputs. (8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction. (9) All models are fully operational and meet published specifications, including "cold start" at -40 C. Maximum power requires that the package temperature of all on-board components must never exceed +128C. (10) Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. (11) The converter is normally specified with the Input/Output filtering listed in Note 1. Higher capacitive load will reduce noise but at the expense of delayed settling time, extended turn-on time and slower transient response. Use only as much output filtering as needed and no more. Thoroughly test your system under full load with all components installed. Low ESR capacitors with high capacitance may degrade dynamic performance. (12) "Hiccup" overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcurrent condition still exists, the restart current will be removed and then tried again. This short current repeating pulse prevents overheating and damaging the converter. Output current limit and short circuit protection is non-latching. Once the fault is removed, the converter immediately recovers normal operation. (13) Do not exceed maximum power specifications when adjusting the output trim. (14) At zero output current, the output may contain low frequency components which exceed the ripple specification. The output may be operated indefinitely with no load. (15) Input Fusing: If reverse polarity is accidentally applied to the input, a body diode will become forward biased and will conduct considerable current. To ensure reverse input protection, always connect an external input slow-blow fuse in series with the +Vin input. Use approximately twice the full input current rating with nominal input voltage. (16) Output accuracy is dependent on user-supplied trim resistors. To achieve high accuracy, use 1% or better tolerance metal-film resistors. (17.) Always connect the sense pins. If they are not connected to a remote load, wire each sense pin to its respective voltage output at the converter pins.
Soldering Guidelines
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100 C. for 30 minutes). Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders: Maximum Preheat Temperature Maximum Pot Temperature Maximum Solder Dwell Time 115 C. 270 C. 7 seconds
For Sn/Pb based solders: Maximum Preheat Temperature Maximum Pot Temperature Maximum Solder Dwell Time 105 C. 250 C. 6 seconds
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 5 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
Technical Notes
Removal of Soldered Converters from Printed Circuit Boards Should removal of the converter from its soldered connection be needed, thoroughly de-solder the pins using solder wicks or de-soldering tools. At no time should any prying or leverage be used to remove boards that have not been properly de-soldered first. Input Source Impedance These converters must be driven from a low ac-impedance input source. The DC/DC's performance and stability can be compromised by the use of highly inductive source impedances. The input circuit shown in Figure 2 is a practical solution that can be used to minimize the effects of inductance in the input traces. For optimum performance, components should be mounted close to the DC/DC converter. I/O Filtering, Input Ripple Current, and Output Noise All models in this Series are tested/specified for input ripple current (also called input reflected ripple current) and output noise using the circuits and layout shown in Figures 2 and 3. External input capacitors (CIN in Figure 2) serve primarily as energy-storage elements. They should be selected for bulk capacitance (at appropriate frequencies), low ESR, and high rms-ripple-current ratings. The switching nature of DC/DC converters requires that dc voltage sources have low ac impedance as highly inductive source impedance can affect system stability. In Figure 2, CBUS and LBUS simulate a typical dc voltage bus. Your specific system configuration may necessitate additional considerations. In critical applications, output ripple/noise (also referred to as periodic and random deviations or PARD) can be reduced below specified limits using filtering techniques, the simplest of which is the installation of additional external output capacitors. Output capacitors function as true filter elements and should be selected for bulk capacitance, low ESR, and appropriate frequency response. In Figure 3, the two copper strips simulate real-world pcb impedances between the power supply and its load. Scope measurements should be made using BNC connectors or the probe ground should be less than 1/2 inch and soldered directly to the fixture. All external capacitors should have appropriate voltage ratings and be located as close to the converter as possible. Temperature variations for all relevant parameters should be taken into consideration. OS-CONTM organic semicon-
ductor capacitors (www.sanyo.com) can be especially effective for further reduction of ripple/noise. The most effective combination of external I/O capacitors will be a function of line voltage and source impedance, as well as particular load and layout conditions. Start-Up Threshold and Undervoltage Shutdown Under normal start-up conditions, these converters will not begin to regulate properly until the ramping input voltage exceeds the Start-Up Threshold. Once operating, devices will turn off when the applied voltage drops below the Undervoltage Shutdown point. Devices will remain off as long as the undervoltage condition continues. Units will automatically re-start when the applied voltage is brought back above the Start-Up Threshold. The hysteresis built into this function avoids an indeterminate on/off condition at a single input voltage. See Performance/Functional Specifications table for actual limits. Start-Up Time The VIN to VOUT Start-Up Time is the interval between the point at which a ramping input voltage crosses the Start-Up Threshold voltage and the point at which the fully loaded output voltage enters and remains within its specified accuracy band. Actual measured times will vary with input source impedance, external input capacitance, and the slew rate and final value of the input voltage as it appears to the converter. The On/Off to VOUT start-up time assumes that the converter is turned off via the Remote On/Off Control with the nominal input voltage already applied. On/Off Control The primary-side, Remote On/Off Control function can be specified to operate with either positive or negative polarity. Positive-polarity devices ("P" suffix) are enabled when the on/off pin is left open or is pulled high. Positive-polarity devices are disabled when the on/off pin is pulled low (with respect to -Input). Negative-polarity devices are off when the on/off pin is high and on when the on/off pin is pulled low. See Figure 4. Dynamic control of the remote on/off function is best accomplished with a mechanical relay or an open-collector/open-drain drive circuit (optically isolated if appropriate). The drive circuit should be able to sink appropriate current (see Performance Specifications) when activated and withstand appropriate voltage when deactivated.
+SENSE +OUTPUT TO OSCILLOSCOPE CURRENT PROBE LBUS CBUS - 1 See specs for component values. -INPUT CIN
7 8
COPPER STRIP
C1 3 +INPUT 4 -OUTPUT 5 -SENSE
C2
SCOPE
RLOAD
+ VIN
COPPER STRIP
C1 = 1F CERAMIC C2 = 10F TANTALUM LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 2. Measuring Input Ripple Current
Figure 3. Measuring Output Ripple/Noise (PARD)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 6 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
Sense Input Note: The sense and VOUT lines are internally connected through low-value resistors. Nevertheless, if sense is not used for remote regulation, the user must connect + sense to + VOUT and -sense to -VOUT at the converter pins. Sense is intended to correct small output accuracy errors caused by the resistive ohmic drop in output wiring as output current increases. This output drop (the difference between Sense and VOUT when measured at the converter) should not be allowed to exceed 0.5V. Sense is connected at the load and corrects for resistive errors only. Be careful where it is connected. Any long, distributed wiring and/or significant inductance introduced into the Sense control loop can adversely affect overall system stability. If in doubt, test the application, and observe the DC/DC's output transient response during step loads. There should be no appreciable ringing or oscillation. You may also adjust the output trim slightly to compensate for voltage loss in any external filter elements. Do not exceed maximum power ratings. Current Limiting When power demands from the output falls within the current limit inception range for the rated output current, the DC/DC converter will go into a current limiting mode. In this condition the output voltage will decrease proportionately with increases in output current, thereby maintaining a somewhat constant power dissipation. This is commonly referred to as power limiting. Current limit inception is defined as the point where the full-power output voltage falls below the specified tolerance. If the load current being drawn from the converter is significant enough, the unit will go into a short circuit condition. See "Short Circuit Condition." Short Circuit Condition When a converter is in current limit mode the output voltages will drop as the output current demand increases. If the output voltage drops too low, the magnetically coupled voltage used to develop primary side voltages will also drop, thereby shutting down the PWM controller. Following the specified time-out period, the PWM will restart, causing the output voltages to begin ramping to their appropriate values. If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling is referred to as "hiccup" mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. This converter is capable of enduring an indefinite short circuit output condition. Thermal Shutdown These converters are equipped with thermal-shutdown circuitry. If the internal temperature of the DC/DC converter rises above the designed operating Trim adjustments greater than the specified trim range can have an adverse affect on the converter's performance and are not recommended. Excessive voltage differences between VOUT and Sense, in conjunction with trim adjustment of the output voltage, can cause the overvoltage protection circuitry to activate (see Performance Specifications for overvoltage limits). Temperature/power derating is based on maximum output current and voltage at the converter's output pins. Use of the trim and sense functions can cause output voltages to increase, thereby increasing output power beyond the converter's specified rating, or cause output voltages to climb into the output overvoltage region. Therefore: (VOUT at pins) x (IOUT) d rated output power The Trim pin is a relatively high impedance node that can be susceptible to noise pickup when connected to long conductors in noisy environments.
Figure 4. Driving the Remote On/Off Control Pin
temperature (See Performance Specifications), a precision temperature sensor will power down the unit. When the internal temperature decreases below the threshold of the temperature sensor, the unit will self start. Output Overvoltage Protection The output voltage is monitored for an overvoltage condition via magnetic coupling to the primary side. If the output voltage rises to a fault condition, which could be damaging to the load circuitry (see Performance Specifications), the sensing circuitry will power down the PWM controller causing the output voltage to decrease. Following a time-out period the PWM will restart, causing the output voltage to ramp to its appropriate value. If the fault condition persists, and the output voltages again climb to excessive levels, the overvoltage circuitry will initiate another shutdown cycle. This on/off cycling is referred to as "hiccup" mode. Input Reverse-Polarity Protection If the input-voltage polarity is accidentally reversed, an internal diode will become forward biased and likely draw excessive current from the power source. If the source is not current limited or the circuit appropriately fused, it could cause permanent damage to the converter. Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of a sustained, non-current-limited, input-voltage polarity reversal exists. For these converters, slow-blow fuses are recommended with values no greater than twice the maximum input current. Trimming Output Voltage These converters have a trim capability that enables users to adjust the output voltage over a limited range (refer to the trim equations). Adjustments to the output voltage can be accomplished with a single fixed resistor as shown in Figures 5 and 6. A single fixed resistor can increase or decrease the output voltage depending on its connection. Resistors should be located close to the converter and have TCR's less than 100ppm/C to minimize sensitivity to changes in temperature. If the trim function is not used, leave the trim pin open. Standard units have a "positive trim" where a single resistor connected from the Trim pin to the +Sense will increase the output voltage. A resistor connected from the Trim Pin to the -Sense will decrease the output voltage.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 7 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
1 -INPUT +OUTPUT 8 1 -INPUT +OUTPUT 8
+SENSE 2 ON/OFF CONTROL
7 2 ON/OFF CONTROL
+SENSE
7
TRIM
6 RTRIM UP
TRIM
6 RTRIM DOWN
LOAD
LOAD
-SENSE 3 +INPUT
5 3 +INPUT
-SENSE
5
-OUTPUT
4
-OUTPUT
4
Figure 5. Trim Connections To Increase Output Voltages Using Fixed Resistors
Figure 6. Trim Connections To Decrease Output Voltages Using Fixed Resistors
Trim Up
Trim Down
HPQ-3.3/50-D48
RT UP (k ) = 16.863(1+) 1.225x - 5.11 -10.22 RTDOWN (k ) = 5.11 -10.22
where is the absolute value of 3.3 - VOUT 3.3 ( is always positive)
(
)
TYPICAL PERFORMANCE CURVES HPQ-3.3/50-D48 Efficiency vs Line Voltage and Load Current @ +25C HPQ-3.3/50-D48 Maximum Current Temperature Derating (Vin=48V, no baseplate, longitudinal air flow)
95 90 85 Efficiency (%) 80 75 70 65 5 10 15 20 25 30 35 40 45 50 Load Current (Amps) Power Dissipation VIN = 48 V VIN = 75 V VIN = 48 V VIN = 36 V 24 22 20 18 Loss (Watts) 16 14 12 10 8 6 4 2
50 45 40 Output Current (Amps) 35 30 25 20 15 10 30 40 50 60 70 80 Ambient Temperature (C) 100 LFM 200 LFM 300 LFM 400 LFM
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 8 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
Transient Response
Transient Response (25% Load Step) Enable Start-up
Transient Response (50% Load Step)
Enable Start-up (Vin=48V Iout=0A) Ripple and Noise (1uF Ceramic plus 10uF Tantalum)
Enable Start-up (Vin=48V Iout=50A)
Ripple Waveform (Vin=48V Iout=0A)
Ripple Waveform (Vin=48V Iout=50A)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_HPQ Series.A07 Page 9 of 10
HPQ Series
Isolated High Power Quarter Brick DC/DC Converters
USA: Canada: UK: France: Germany: Japan: China: Singapore:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
06/02/08 03/05/09
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2009 Murata Power Solutions, Inc.
www.murata-ps.com
MDC_HPQ Series.A07 Page 10 of 10


▲Up To Search▲   

 
Price & Availability of HPQ-3350-D48PHL1C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X